2009 Dresser-Rand RD9MOQ

2009 Dresser-Rand RD9MOQ

Entre em contacto para saber o preço

Local:Alemanha

Available quantity:3

Descrição

3X Identical Steam Turbine sets


Each steam turbine set is a complete system except the boiler for the steam generation. If sufficient water vapour is already available from another source, this can also be used. In this case, a boiler is no longer required.

 

The three sets have never been run (like new), however, this sets are already more than 10 years old (year of production 2009). The project for which this sets were purchased has never been implemented. The steam turbine sets are running on 60 Hz.


Depending on the country, where the steam turbine sets should be used, they may have to be converted to 50 Hz (replacing the gearbox and the clutch of the generator). This is possible and can be done by experienced companies. We can recommend a German company that has extensive experience in the errection and maintenance of this type of steam turbine.

 

The unused steam turbine sets are packed in wooden crates in a seaworthy condition. The individual parts are packed airtight in aluminum-coated plastic.

 

If an interested party expresses a serious interest in purchasing one set, the parts can be unpacked accordingly for an inspection.

 

The unused steam turbine sets are still in good condition. A few years ago, the generators have been tested as good. Out of the former 4 steam turbine sets, one has already been sold four years ago and no negative feedback has been received.

 

Below are a few key data:

 

  • Manufacturer turbine:                          Dresser-Rand
  • TYPE:                                                     RD9MOQ
  • Generator:                                           INDAR Syn. Generator 3 Phases
  • Gearbox:                                              COLOR 4,500 rpm/1,800 rpm
  • Condenser:                                         GEA
  • Grid frequency:                                   60 Hz
  • Capacity:                                             12,3 MW
  • Steam inlet pressure:                          42 bar
  • Temperature:                                       rd. 420 degrees
  • Steam exhaust temperature:               rd. 40 degrees
  • Steam consumption at 9 to 10 MW:    rd. 40 tons
  • Generation:                                         power, no cogeneration of steam



Find more here - https://www.ucymachines.com/


Contact us at - sales@ucymachines.com

Especificações

FabricanteDresser-Rand
ModeloRD9MOQ
Ano2009
CondiçãoUsado
Número de inventário1362