2018 Diener Tetra 100_LF-PC-c
2018 Diener Tetra 100_LF-PC-c
Contact us for price
Location:Hungary
Description
Tetra 100_LF-PC-c
- Year of construction
2018
- Operating hours
Plasma system: 882
Glanded pump: 498
SURFACE TREATMENT
WITH PLASMA system FROM DIENER ELECTRONIC
Condition
The corrosive gas-resistant system has a special vacuum chamber measuring 400 mm x 625 mm x 400 mm (W x D x H). The vacuum chamber can be fully opened using an automated drawer. A holding frame for substrates is located vertically at the end of the drawer on the system side. It forms the counter electrode to the electrode in the vacuum chamber. Both electrodes are equipped with a cooling water circuit. Substrate holders with openings in the direction of the electrode can be mounted in the holding frame of the drawer. Samples that point towards the electrode through the openings in the holding frame can be treated in the plasma process. The remaining volume of the drawer is in a high vacuum during the process, but is not exposed to the plasma itself. The drawer also has flanges for inserting larger samples into the plasma chamber. Access to the drawer area is monitored by a safety system based on light barriers.
There is a leakage at one valve. For this reason, the system could not be put into operation and tested in preparation.
Dimensions and weights if known
Plasma system Tetra 100_LF-PC-c
- Dimensions (W x D x H) 600 mm x 1200 mm x 2100 mm
- Weight: approx. 350 kg
Edwards iH1800 glanded pump
- Dimensions: (L (to the housing of the exhaust system) x W x H (to the frequency converter))
986 (1059) mm x 470 mm x 888 (1094) mm
- Weight: 502 kg
Rittal SK Chiller TopTherm (SK 3334.600)
- Dimensions: (W x D x H) 602 mm x 645 mm x 676 mm
- Weight / operating weight: 125 kg / 155 kg
Van Der Heijden mobile refrigerator (laboratory chiller) Type: 0000-A-KH-B400-TT-12-54-62
- Dimensions: (W x D x H) 360 mm x 470 mm x 590 mm
- Weight: 46 kg
- Basic technical information on the plasma systems
- Plasma system type Tetra 100 (Diener electronic Vertriebs GmbH + Co. KG), corrosive gas version
- Connection 400 V / 32 A
- Full PC control with remote maintenance option via TeamViewer
- Generator type A (80 kHz, 0 -1000 W)
- Electrode, water-cooled, aluminium, 314 mm x 25 mm x 318 mm (W x D x H)
- Special vacuum chamber, stainless steel, sight glasses at the rear, with drawer, automated and electrically driven,
Dimensions W: 400 mm, D: 625 mm, H: 400 mm (volume: approx. 100 litres)
- Water-cooled sample holder, incl. thermometer (integrated in control software)
- Dosing for Silan A 174 (incl. heating cartridge, dosing unit, software integration, supply to chamber via separate gas inlet)
- Pressure reducer for oxygen, noble gases (incl. inlet and outlet pressure gauges)
- Pressure reducer SF6, C4F8
- 400 V Edwards iH1800 glanded pump, suction capacity 1800 m3/h
- Rittal SK Chiller TopTherm (SK 3334.600)
- Van Der Heijden mobile cooling unit (laboratory chiller) type: 0000-A-KH-B400-TT-12-54-62, setting range: -5°C - +25°C,
Pump capacity max. 28 l/min
- Activated charcoal filter KF 40
- Software language: German, English, Hungarian
- Operating instructions in German
- Maintenance status
Last maintenance by manufacturer 17.10.2019 (annual maintenance cycle was cancelled due to subsequent system shutdown)
- Spare parts supplied
- 1 x electrode, water-cooled, titanium, 314 mm x 25 mm x 318 mm (W x D x H)
- 4 x electrode retaining bolts
- 1 x substrate holder
Find more here - https://www.ucymachines.com/
Contact us at - sales@ucymachines.com
Specifications
Manufacturer | Diener |
Model | Tetra 100_LF-PC-c |
Year | 2018 |
Condition | Used |
Stock Number | 994 |